E2
Landmann Cabinet Temperature Sensor (NTC) Short Circuit or Out-of-Range Reading

Display shows E2 and the smoker overheats or shuts down shortly after starting, sometimes with unusually high internal temperature readings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted temperature sensor probe, Melted sensor wiring contacting chassis, Moisture ingress in sensor connector, Faulty control board interpreting sensor signal

How to Fix / Troubleshooting

Safety first: Disconnect power and let the smoker cool fully. Do not operate the smoker if it is overheating.

Steps to diagnose and correct:

  • Access the sensor wiring: Remove the rear or side service panel to expose the wiring from the inner temperature probe to the control board.
  • Inspect for shorts: Look for melted insulation where the sensor wires pass near the heating element or metal edges. If bare wires are touching each other or the metal cabinet, separate them and wrap with high-temperature electrical tape or replace the damaged harness.
  • Check the sensor body: From inside the cabinet, inspect the probe for signs of overheating, cracking, or deformation. Replace if damaged.
  • Test resistance: With the sensor unplugged from the board, measure resistance across the two leads. A reading near 0 Ω indicates a shorted sensor. Replace the sensor if shorted or if resistance is far outside Landmann’s specified range.
  • Dry out moisture: If the connector area is wet from cleaning or weather, dry thoroughly with a cloth and allow the smoker to air dry for several hours before retesting.
  • Reassemble and test: Reconnect the sensor, secure wiring away from hot surfaces, reinstall the panel, and test at a low temperature setting.

When to seek service: If a known-good sensor still triggers E2, the control board’s sensor circuit is likely defective and the main control board should be replaced by a qualified technician.