E009
Alfen
Internal CAN / RS485 Communication Failure
E009 displayed; charger indicates internal communication error and is unresponsive to start commands.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose low-voltage harness between control PCB and metering module, Faulty internal energy meter, Firmware mismatch between modules, Damaged communication transceiver on main PCB
How to Fix / Troubleshooting
Safety first: Disconnect power before handling internal connectors or boards.
- Step 1 – Power cycle: Turn off the charger at the breaker for 5 minutes, then power back on. Many transient communication faults clear after a reboot.
- Step 2 – Check low-voltage connectors: With power OFF, open the enclosure and gently reseat all low-voltage plugs between the main PCB, display module, RFID reader, and internal meter. Ensure locking tabs click into place.
- Step 3 – Inspect communication cabling: Look for pinched, cut, or abraded twisted-pair cables used for CAN/RS485 inside the unit.
- Step 4 – Firmware check: Using the Alfen installer tool, verify that all modules are running compatible firmware versions. Update firmware according to Alfen’s official procedure if required.
- Step 5 – Module isolation: A technician can temporarily disconnect optional modules (e.g., RFID, external meter interface) to see if E009 clears, helping to identify the faulty module.
- When to call a technician: Persistent E009 errors usually require professional diagnostics and possible replacement of the internal meter or main PCB.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Internal Energy Meter Module
Check Price on Amazon
We may earn a commission from links on this page.