F5
Protherm
Flow Temperature Sensor Fault (NTC Open/Short)
F5 displayed, furnace will not start, fan may not run
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective flow NTC sensor on Protherm flow pipe, Broken or shorted sensor wiring, Poor connector contact at PCB, Water ingress into sensor plug
How to Fix / Troubleshooting
Safety first: Isolate power. For hydronic systems, allow water to cool before touching pipework.
- Step 1 – Locate flow sensor: On Protherm hydronic furnaces, the flow NTC is usually clipped to or inserted into the flow pipe leaving the heat exchanger. Follow the two‑core cable from the PCB to find it.
- Step 2 – Inspect wiring: Check the cable for cuts, crushed sections, or signs of moisture. Reseat the connector at both the sensor and the PCB.
- Step 3 – Basic sensor check: With power off, disconnect the sensor and measure its resistance using a multimeter. Compare with the temperature/resistance table in the service manual. An open circuit or near‑zero ohms indicates a faulty sensor.
- Step 4 – Replace sensor if faulty: Remove the old NTC (unscrew or unclip). If it is a wet‑pocket sensor, be prepared for some water loss and close isolation valves if available. Install the new Protherm‑compatible NTC with thermal paste if required.
- Step 5 – Reset and test: Restore power and reset the fault. If F5 persists with a new sensor and good wiring, the PCB input may be defective and should be checked by a technician.