Possible Causes

Blown internal fuse on control board, Faulty power transformer on PCB, Loose mains terminal connection, Tripped GPO or circuit breaker

How to Fix / Troubleshooting

Safety first: Disconnect power at the wall outlet or circuit breaker before removing any covers. Garage door springs are under high tension; do not loosen or adjust torsion springs yourself.

Steps to check power supply:

  • 1. Verify outlet power: Plug a lamp or phone charger into the same power point as the Gliderol opener. If it does not work, reset the breaker or RCD and test again.
  • 2. Inspect power cord and plug: With power disconnected, check the opener’s power cord for cuts, burns, or crushed sections. Ensure the plug fits firmly in the outlet.
  • 3. Check terminal block: Remove the opener’s cover (usually a few screws). Locate the mains terminal block on the Gliderol control board and confirm all live/neutral/earth screws are tight and wires are not burnt.
  • 4. Inspect internal fuse: Many Gliderol units have a small glass or blade fuse on the PCB. If it appears blackened or the filament is broken, replace it with the exact same rating (printed on the fuse or board). Never bypass the fuse.
  • 5. Check transformer (if fitted): On older Gliderol sectional and roller door openers, a small step‑down transformer feeds the logic board. If it is discoloured, smells burnt, or rattles, it may be open-circuit and require replacement of the transformer or entire control board.

When to stop: If the new fuse blows immediately or you see burnt tracks/components on the PCB, stop and contact a Gliderol service technician. Further operation may be unsafe.