COMM
Jandy
Communication Failure with Automation System
Pump does not respond to Jandy AquaLink automation; display shows COMM ERROR or NO COMM.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Disconnected or damaged RS-485 cable, Incorrect RS-485 polarity, Faulty AquaLink PCB, Incorrect address or configuration in controller
How to Fix / Troubleshooting
Safety first: Turn off power to both the pump and the AquaLink control panel before working on low-voltage wiring.
- Inspect RS-485 wiring:
- Locate the RS-485 terminals on the Jandy pump drive and on the AquaLink board.
- Ensure the A/B (or +/–) wires are landed on matching terminals at both ends.
- Check for loose screws, corrosion, or broken conductors.
- Check cable integrity:
- Follow the cable run and look for cuts, rodent damage, or splices.
- Replace the cable if insulation is damaged or conductors are exposed.
- Verify addressing and settings:
- In the AquaLink menu, confirm the pump is enabled and correctly addressed as a Jandy VS pump.
- On the pump, ensure it is set to external control mode if required.
- Power cycle system:
- After correcting wiring, power up the AquaLink first, then the pump.
- Allow a few minutes for communication to establish.
- If COMM error persists: The AquaLink main board or the pump’s communication interface may be faulty. Contact a Jandy-authorized service technician for board-level diagnostics.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
RS-485 Communication Cable
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements