E7
SMEG Induction Coil Temperature Sensor Fault

Induction zone shows E7 and does not heat properly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted NTC sensor on coil, Broken sensor wiring, Sensor detached from coil, Faulty power module sensor input

How to Fix / Troubleshooting

Safety first: Disconnect power and wait for capacitors to discharge before opening the cooktop.

Steps:

  • Access coil area: Remove the cooktop from the counter and take off the bottom cover to expose the coils.
  • Locate sensor: Find the small sensor (usually clipped or glued) on the affected coil. Check that it is firmly attached and not hanging loose.
  • Inspect wiring: Follow the sensor wires back to the power module. Look for cuts, burns, or loose connectors.
  • Replace sensor: If the sensor is damaged or detached, replace the coil temperature sensor or the entire coil assembly, depending on SMEG design.
  • Module check: If a new sensor does not resolve E7, the power module input may be defective and the module should be replaced.

Warning: Incorrect sensor repair can lead to overheating. If unsure, use a professional technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Induction Coil Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements