CC
GE Monogram Compressor or Cooling Performance Fault

Display shows CC; refrigerator or freezer temperature is too warm; food may be soft or thawing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Condenser coils clogged with dust, Condenser fan motor not running, Evaporator fan motor failure, Low refrigerant charge or sealed system leak

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before cleaning coils or accessing fans. Do not attempt sealed system repairs (refrigerant) unless you are EPA-certified; this requires a professional.

Step 1 – Check door usage and loading:

  • Ensure doors are not being left open for extended periods.
  • Verify the unit is not overloaded with warm food, which can temporarily raise temperatures.
  • Allow 24 hours after large grocery loads for temperatures to stabilize.

Step 2 – Clean the condenser coils:

  • Pull the refrigerator away from the wall carefully, protecting the floor and water line.
  • Remove the lower rear access panel if present.
  • Use a coil brush and vacuum to remove dust and pet hair from the condenser coils and surrounding area.
  • Ensure the area around the refrigerator has adequate ventilation.

Step 3 – Check the condenser fan:

  • With the rear panel removed, plug the unit back in briefly.
  • When the compressor runs, the condenser fan motor should also run and blow air across the coils.
  • If the fan is not running, spins slowly, or is noisy, unplug the unit and inspect for obstructions. Replace the fan motor if defective.

Step 4 – Check the evaporator fan(s):

  • Open the freezer and listen for the evaporator fan when the compressor is running and the door switch is held closed.
  • If no fan noise is heard, remove the interior rear panel and inspect the fan for ice blockage or failure.
  • Replace the evaporator fan motor if it does not run freely or fails under power.

Step 5 – Evaluate for sealed system issues:

  • If fans and coils are clean and operating but cooling is still poor, look for signs of only partial frost on the evaporator coil (requires panel removal).
  • A small patch of frost instead of an even frost pattern often indicates low refrigerant or a sealed system restriction.

When to call a technician: Any suspected sealed system problem (low refrigerant, compressor failure, capillary tube restriction) must be handled by a certified refrigeration technician. If CC persists after cleaning coils and verifying fans, schedule service.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Condenser Fan Motor
Check Price on Amazon