E10
Atlantic
Low Voltage or Power Supply Instability
E10 error and thermostat reports power supply fault or keeps turning off when HVAC starts.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Undersized or failing 24 V AC transformer, Loose low‑voltage connections at backplate, Short circuit on control wiring, Internal power regulator fault on thermostat PCB
How to Fix / Troubleshooting
Safety first: Isolate power to the HVAC system and thermostat at the breaker. Low‑voltage circuits can still cause damage if shorted.
- Step 1 – Inspect wiring: Remove the thermostat and check that R, C, and other control wires are firmly connected and not frayed or touching each other. Correct any shorts.
- Step 2 – Measure transformer output: At the HVAC control board or transformer, measure the AC voltage. It should match the rated value (commonly 24 V AC). If significantly low under load, replace the transformer.
- Step 3 – Check wire gauge and length: Very long runs with thin wire can cause voltage drop. If the thermostat is far from the transformer, consider using thicker cable or relocating the transformer.
- Step 4 – Test with spare transformer: Temporarily power the thermostat from a separate known‑good 24 V AC transformer to see if E10 disappears. If it does, the original supply is faulty.
- Step 5 – Replace thermostat: If supply voltage is stable and within spec but E10 persists, the internal power regulator or rectifier on the thermostat PCB may be defective. Replace the thermostat module.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Internal Power Supply Circuit / External 24 V Transformer
Check Price on Amazon
We may earn a commission from links on this page.