E15
Goodman
Common Wire Detection Fault
Thermostat displays E15 and indicates C-wire or power stealing error; may run on batteries only if equipped
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Missing C wire from Goodman furnace/air handler, Loose C terminal connection, Shared transformer with incompatible equipment, Incorrect use of power-stealing adapters
How to Fix / Troubleshooting
Safety first: Turn off power to the furnace/air handler at the breaker before adding or changing any thermostat wiring.
Steps to resolve E15 C-wire fault:
- 1. Confirm C terminal at furnace: Open the Goodman furnace/air handler panel and locate the control board. Identify the C terminal and verify a wire is connected and firmly secured.
- 2. Verify C at thermostat: Ensure the same conductor is landed on the C terminal at the thermostat. Label wires if necessary to avoid confusion.
- 3. Add C wire if missing: If no spare conductor is available in the thermostat cable, consider pulling a new 5–8 conductor cable or using a Goodman-approved C-wire adapter module at the furnace.
- 4. Check for shared transformers: If multiple systems share the same thermostat, ensure their transformers are properly phased and commons are tied together per Goodman and accessory manufacturer instructions.
- 5. Remove unauthorized adapters: Remove any third-party power-stealing devices that may interfere with proper C-wire detection.
- 6. Power up and test: Restore power and verify that the thermostat no longer reports E15 and remains powered with the display stable.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Thermostat cable (18/5 or 18/8 low-voltage wire)