E03
Mysa Line Voltage Detection Error

Thermostat displays E03 and will not turn the heater on or off correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect line-voltage wiring, Open neutral or line conductor, Internal line-sensing circuit failure on the thermostat PCB

How to Fix / Troubleshooting

Safety first: This is a line-voltage thermostat (typically 120/240 V). Turn OFF the circuit breaker and verify power is off with a non-contact voltage tester before touching any wires.

Steps to check:

  • Verify wiring against Mysa diagram: Remove the thermostat from the wall plate. Confirm that LINE (L) and LOAD wires are connected to the correct terminals as per the Mysa installation guide. Ensure neutral (if used) is correctly landed.
  • Check for loose connections: Tug each conductor gently to ensure it is firmly clamped in the terminal. Re-strip and re-terminate any damaged or oxidized copper.
  • Confirm voltage at the box: With the thermostat removed and power ON (only if you are qualified), measure voltage between line and neutral (or line-to-line for 240 V). It should match the heater rating. If no voltage is present, the issue is upstream (breaker, junction box).
  • Inspect for signs of overheating: With power OFF, look for discoloration or melting on the thermostat terminals or PCB near the line-sensing components.

If wiring and supply voltage are correct and E03 persists, the internal line-voltage detection circuit on the main control board is likely damaged. Replacement of the thermostat is recommended.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (Line-Sensing Circuit)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements