E5
Tuya Output Relay or Triac Overcurrent / Short Circuit Protection

Thermostat displays E5 and does not energize the heating/cooling output; may be accompanied by a hot or buzzing thermostat

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted heating load or HVAC control circuit, Overloaded relay beyond rated current, Shorted triac on Tuya thermostat PCB, Wiring fault between thermostat and load

How to Fix / Troubleshooting

Safety first: Immediately switch off the circuit breaker feeding the thermostat and the connected load. Do not continue to reset power until the fault is found.

Steps to troubleshoot:

  • Remove the thermostat from the wall and inspect the wiring terminals for burnt insulation, melted plastic, or loose strands causing shorts.
  • Verify that the connected load (e.g., electric floor heating mat, boiler control input) does not exceed the thermostat's rated current (commonly 3–16A depending on model).
  • Disconnect the load wires from the thermostat output terminals.
  • With the load disconnected, restore power and see if the E5 code clears. If it clears, the problem is likely in the load or field wiring.
  • Insulation-test or continuity-test the load circuit with a multimeter or megohmmeter; repair any shorts or damaged cables.
  • If E5 persists even with no load connected, the thermostat's relay or triac is likely damaged; replace the thermostat.

Note: Overcurrent faults can be dangerous. If you see charring or smell burning, have a licensed electrician inspect the circuit.