E14
Triangle Tube
Fan Speed / Combustion Blower Fault
E14 error, unit may not modulate correctly or may shut down under high load.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed combustion blower motor, Blocked fan wheel, Faulty fan speed feedback signal, Loose blower connector
How to Fix / Troubleshooting
Safety: Disconnect power before removing the blower assembly. Sharp metal edges may be present.
- 1. Listen for blower operation: On a call for heat, the combustion blower should start and ramp up. If it hums, grinds, or does not start, suspect a blower issue.
- 2. Inspect venting: Ensure intake and exhaust are clear; a heavily restricted vent can overload the blower.
- 3. Check wiring: Access the blower connector at the control board and at the blower. Reseat connectors and inspect for heat damage or corrosion.
- 4. Inspect fan wheel: With power off, remove the blower and check the fan wheel for debris, broken blades, or binding. Clean dust and lint from the housing.
- 5. Reassemble and test: Reinstall the blower, restore power, and test operation. If E14 persists and the blower does not reach commanded speed, the blower or control board may need replacement.
- 6. Professional replacement: Combustion blower replacement and calibration should be performed by a qualified technician following Triangle Tube procedures.