F2
AEG Outdoor Ambient or Coil Sensor Fault (Model-dependent)

F2 error; unit may stop during heating or show incorrect defrost behaviour.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor ambient NTC sensor, Sensor dislodged from mounting point, Damaged sensor cable, Faulty outdoor PCB sensor circuit

How to Fix / Troubleshooting

Safety: Turn off the outdoor isolator before opening the outdoor unit.

  • Identify sensor type: Consult the AEG service label or manual to confirm whether F2 refers to ambient or coil sensor on your model.
  • Locate sensor: Ambient sensors are usually clipped near the air intake grille; coil sensors are attached to the condenser coil.
  • Check attachment: Ensure the sensor is firmly clipped and not dangling. Reattach if necessary.
  • Inspect cable: Look for UV damage, cracks, or rodent bites on the cable. Replace if damaged.
  • Test resistance: With a multimeter, check sensor resistance at outdoor temperature. Replace with a matching AEG outdoor NTC sensor if readings are abnormal.
  • If F2 remains: The outdoor PCB may require replacement by a professional.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Ambient / Coil Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.