E6
Airwell
Outdoor Unit Communication or Feedback Fault
Indoor unit shows E6; compressor may not start or may shut down; sometimes accompanied by outdoor unit not responding.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty outdoor PCB, Damaged communication wiring, Incorrect grounding or electrical noise, Failed outdoor control transformer or power supply
How to Fix / Troubleshooting
Safety: Isolate power at the main breaker. Outdoor units contain high-voltage components; do not touch capacitors or power modules when energized.
Steps:
- 1. Confirm E5 vs E6: Some Airwell models differentiate between general communication (E5) and outdoor feedback (E6). Check the user manual for your exact model.
- 2. Inspect outdoor PCB area: Remove the outdoor unit service panel. Look for obvious damage: burnt components, insect nests, water ingress, or corrosion on the PCB.
- 3. Check connectors: Ensure all multi-pin connectors between the outdoor PCB, compressor, fan motor, and sensors are fully seated.
- 4. Verify grounding: Confirm that the outdoor unit is properly grounded and that the ground wire is securely attached. Poor grounding can cause communication noise.
- 5. Inspect low-voltage wiring: Follow the communication wires from the terminal block to the PCB. Look for breaks or loose plugs.
- 6. Power supply check (advanced): With a multimeter and appropriate safety precautions, a technician can verify that the outdoor PCB is receiving correct DC supply voltages. If missing, the PCB or internal power supply is faulty.
- 7. Replace outdoor PCB if necessary: If all wiring is intact and the PCB shows visible damage or fails power checks, replacement of the outdoor main PCB is indicated. This should be done by a qualified technician due to high-voltage and refrigerant-related risks.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Outdoor Main PCB
Check Price on Amazon