F9
Airwell
EEPROM / Configuration Data Error
Indoor unit displays F9; system may not start or may shut down unexpectedly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted EEPROM on indoor PCB, Incorrect PCB replacement without proper configuration, Voltage surge or static damage, Manufacturing defect in memory chip
How to Fix / Troubleshooting
Safety: Turn off power at the breaker before accessing the PCB.
Steps:
- 1. Power reset: Turn off power for 10–15 minutes, then restore. If F9 clears temporarily, note any pattern of recurrence.
- 2. Check PCB history: If the indoor PCB was recently replaced, verify that the correct Airwell part number was used and that any required configuration (DIP switches, jumpers) matches the original board.
- 3. Visual inspection: Look for damage around the memory IC on the PCB (often a small 8-pin chip).
- 4. Professional reprogramming/replacement: EEPROM faults usually require PCB replacement or reprogramming with Airwell service tools. Contact an authorized service center.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Indoor Main PCB (EEPROM Section)
Check Price on Amazon
We may earn a commission from links on this page.