H7
Airwell Outdoor Fan Motor Feedback Fault

Indoor unit displays H7; outdoor fan may not run correctly; system may overheat.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective DC outdoor fan motor, Faulty Hall sensor, Loose or corroded fan connector, Outdoor PCB fan driver failure

How to Fix / Troubleshooting

Safety: Isolate power at the breaker. Outdoor fan blades are sharp.

Steps:

  • 1. Inspect fan area: Remove the outdoor panel and check for debris blocking the fan.
  • 2. Check wiring: Locate the fan motor connector on the PCB. Reseat it and inspect for corrosion or burning.
  • 3. Manual spin: Rotate the fan blade by hand. If stiff, the motor bearings may be failing.
  • 4. Replace fan motor: Install a new Airwell outdoor DC fan motor if the existing one is seized or not starting.
  • 5. PCB diagnosis: If a new motor does not resolve H7, the outdoor PCB fan driver is likely faulty and needs replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor DC Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.