Airwell Temperature Sensing / Calibration Error

Indoor unit displays correct temperature but actual room temperature is much higher or lower.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Drifted room temperature sensor, Sensor located in poor airflow area, Heat sources near sensor, Faulty indoor PCB ADC circuit

How to Fix / Troubleshooting

Safety: Turn off power before accessing the sensor or PCB.

Steps:

  • 1. Compare temperatures: Use a reliable room thermometer placed away from the unit to compare with the displayed temperature.
  • 2. Inspect sensor placement: Ensure the room sensor is in the return air path and not touching the coil or metal parts.
  • 3. Clean dust: Dust on the sensor can insulate it. Gently clean the sensor with a soft brush.
  • 4. Replace sensor: If readings are consistently off by several degrees, replace the room temperature sensor with a compatible Airwell NTC.
  • 5. PCB issue: If a new sensor does not correct the error, the indoor PCB's measurement circuit may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Room Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements