Amana
Condensate Drainage Failure
Amana air conditioner leaks water inside the room; water drips from the front panel or onto the floor.
Advertisements
Possible Causes
Clogged condensate drain pan or tube, unit not properly tilted toward outside, cracked drain pan, blocked weep holes in chassis
How to Fix / Troubleshooting
Safety first: Turn off and unplug the unit. Place towels or a tray under the unit to catch water.
Steps to stop indoor water leakage:
- Check unit tilt: For window and PTAC units, ensure the unit is slightly tilted toward the outside so water flows outdoors. Adjust mounting or shims as needed.
- Clean drain pan and holes: Remove the front cover and access the condensate pan under the evaporator coil. Clear debris, algae, and dirt from the pan and drain holes using a small brush or pipe cleaner.
- Flush drain: If a drain tube is attached, disconnect and flush it with warm water and a small amount of bleach to kill algae.
- Inspect for cracks: Examine the plastic drain pan for cracks or warping. Replace the pan if damaged.
Do not seal all weep holes; they are necessary for proper drainage. Only remove obstructions.