Amana Thermostat / Temperature Control Failure

Amana air conditioner runs continuously and does not shut off even when the room feels cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Room thermistor out of calibration, stuck relay on control board, thermostat set too low or miscalibrated, sensor not sensing room air

How to Fix / Troubleshooting

Safety first: Unplug the unit or turn off the breaker before accessing sensors or the control board.

Steps to correct continuous running:

  • Verify settings: Ensure the set temperature is not unrealistically low and that the mode is correct (Cool vs. Fan).
  • Check sensor location: Confirm the room thermistor is in the return air path, not buried in insulation or touching the coil.
  • Test thermistor: Measure resistance and compare to the temperature chart. Replace if out of spec.
  • Inspect control board: If the compressor relay is stuck closed (compressor runs even with power button off), replace the main control board.

Do not attempt to manually pry open relays; replace the board to ensure safe operation.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board
Check Price on Amazon