E9
Amana EEPROM / Memory Error on Control Board

Amana air conditioner displays E9 and may not start the compressor or fan; sometimes occurs after a power surge.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted control board firmware, failed EEPROM chip, power surge damage, defective main control board

How to Fix / Troubleshooting

Safety first: Unplug the unit or switch off the breaker before accessing electronics.

Steps to address E9 (EEPROM/memory error):

  • Power cycle: Disconnect power for at least 5 minutes to allow the control to fully discharge. Restore power and check if the error clears.
  • Check power quality: Verify the outlet or circuit provides correct voltage (typically 115V or 230V depending on model) with a multimeter. Correct any wiring or breaker issues.
  • Inspect control board: Remove the control cover and look for burn marks, swollen components, or insect damage. If present, replace the main control board.
  • Replace control board: If E9 persists after a reset and power is correct, the control board's memory is likely corrupted. Install a new OEM Amana control board programmed for your specific model.

Because this is an internal electronics fault, there is no safe field repair of the EEPROM; replacement of the board is the standard remedy.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements