Amana air conditioner displays E9 and may not start the compressor or fan; sometimes occurs after a power surge.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Unplug the unit or switch off the breaker before accessing electronics.
Steps to address E9 (EEPROM/memory error):
- Power cycle: Disconnect power for at least 5 minutes to allow the control to fully discharge. Restore power and check if the error clears.
- Check power quality: Verify the outlet or circuit provides correct voltage (typically 115V or 230V depending on model) with a multimeter. Correct any wiring or breaker issues.
- Inspect control board: Remove the control cover and look for burn marks, swollen components, or insect damage. If present, replace the main control board.
- Replace control board: If E9 persists after a reset and power is correct, the control board's memory is likely corrupted. Install a new OEM Amana control board programmed for your specific model.
Because this is an internal electronics fault, there is no safe field repair of the EEPROM; replacement of the board is the standard remedy.