F2
Amana High-Pressure Switch Open

Amana central AC or heat pump control shows F2; system may not cool or may shut down intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty outdoor condenser coil, inoperative condenser fan motor, overcharged refrigerant, blocked discharge line, defective high-pressure switch

How to Fix / Troubleshooting

Safety first: Shut off power at the outdoor disconnect and main breaker. Refrigerant circuits are under high pressure; do not open them without proper certification.

Steps to address F2 (high-pressure switch open):

  • Clean condenser coil: Remove debris from the outdoor coil using a garden hose (low pressure) and coil cleaner. Spray from inside out to push dirt away from the fins.
  • Check condenser fan: Restore power briefly and observe if the fan starts and runs when the compressor is energized. If not, test the fan motor and capacitor and replace as needed.
  • Inspect high-pressure switch: With power off, locate the high-pressure switch on the liquid or discharge line. Check wiring and continuity. If the system is cool and pressures should be normal but the switch remains open, replace it.
  • Call a technician for refrigerant issues: If the coil is clean and fan is working but F2 persists, a refrigerant overcharge, restriction, or compressor problem may exist. A licensed HVAC technician must connect gauges and correct the charge.

Never bypass a high-pressure switch; it is a critical safety device protecting the compressor and refrigerant circuit.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

High-Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements