Amana
Evaporator Coil Icing
Frost or ice forms on the indoor coil or front grille of the Amana air conditioner during cooling.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low airflow from dirty filter or blower, low refrigerant charge, operating in very low ambient temperatures, faulty evaporator thermistor
How to Fix / Troubleshooting
Safety first: Turn off the unit and allow ice to melt naturally. Place towels to catch water.
Steps to prevent coil icing:
- Restore airflow: Clean or replace the air filter, clean the evaporator coil, and ensure the blower is running at full speed.
- Avoid low ambient operation: Do not run the unit in cooling mode when outdoor temperatures are below the manufacturer's minimum.
- Check thermistor: Verify the evaporator thermistor is attached to the coil and reading correctly; replace if faulty.
- Refrigerant issues: If icing recurs with good airflow and sensors, have a technician check for low refrigerant or restrictions.
Do not chip ice with tools; this can puncture the coil and cause a refrigerant leak.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Coil Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements