American Standard Breaker Trip on Startup

American Standard air conditioner trips the breaker when it starts

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted compressor, Shorted condenser fan motor, Failing dual run capacitor, Oversized or weak breaker

How to Fix / Troubleshooting

Safety first: Do not repeatedly reset a tripping breaker. Turn off the breaker and outdoor disconnect before inspection.

  • Inspect wiring and components: Remove the outdoor unit panel and look for burnt wires, melted insulation, or obvious shorts to the cabinet.
  • Check capacitor (visual): Replace a bulged or leaking capacitor with the correct rating.
  • Do not upsize breaker: Never install a larger breaker than specified on the American Standard unit nameplate. This is a fire hazard.
  • Professional testing: A technician should test compressor and fan motor windings for shorts to ground and measure inrush current.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor
Check Price on Amazon

We may earn a commission from links on this page.