Possible Causes

Tripped outdoor breaker or blown fuses, Faulty contactor, Broken Y call wire between thermostat and outdoor unit, Failed American Standard outdoor control board

How to Fix / Troubleshooting

Safety first: Turn off power at the main panel before opening any electrical compartments.

  • Check breakers and disconnect: Verify that the outdoor unit breaker is ON and that the disconnect fuses (if present) are intact. Replace blown fuses only with the same type and rating.
  • Inspect Y wiring: Confirm that the Y wire is securely connected at the thermostat, indoor control board, and outdoor contactor coil. Repair any breaks or loose connections.
  • Listen for contactor: With power restored and a call for cooling, listen at the outdoor unit for a click from the contactor. No click suggests a control issue; a click with no compressor/fan suggests a power or component issue.
  • Professional diagnosis: If F03 persists after basic checks, a technician should test the outdoor control board, contactor, and compressor circuit.