American Standard Compressor Not Running

Indoor blower runs but air from vents is warm when cooling is selected

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed dual run capacitor, Failed compressor, Open compressor overload, Faulty American Standard control board not energizing contactor

How to Fix / Troubleshooting

Safety first: Turn off power to the outdoor unit at the disconnect and breaker. Capacitors can retain charge.

  • Observe outdoor unit: With power on and a call for cooling, check if the outdoor fan runs but the compressor is silent. A humming sound followed by a click suggests a start issue.
  • Inspect capacitor (visual): With power off, locate the dual run capacitor. If the top is bulged or leaking, replace it with the same µF and voltage rating.
  • Do not repeatedly restart: If the compressor does not start after capacitor replacement, shut the system down. A technician should test compressor windings and current draw.