E7
Arctic King
Compressor Discharge Temperature Sensor Fault
Display shows E7; unit may run fan only or shut down cooling; sometimes appears after long operation in high heat.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed discharge line thermistor, Sensor dislodged from discharge line, Overheating due to dirty condenser coil, Faulty main PCB sensor circuit
How to Fix / Troubleshooting
Safety: Unplug the unit. The compressor and discharge line can be extremely hot; allow the unit to cool before touching internal components.
Steps to address E7:
- Access compressor compartment: Remove the outer shell (window unit) or rear panel (portable) to expose the compressor and discharge line.
- Locate discharge sensor: Look for a thermistor clipped or strapped to the small-diameter copper line leaving the compressor (discharge line).
- Check mounting and insulation: Ensure the sensor is firmly attached to the line and any insulating sleeve is intact. Re-secure if loose.
- Clean condenser coil: Dust and debris on the condenser coil can cause high discharge temperatures. Use a soft brush and low-pressure air or vacuum to clean the fins thoroughly.
- Test sensor: With power off, disconnect the sensor and measure resistance. Compare to other thermistors in the unit or manufacturer specs. Replace if open, shorted, or clearly out of range.
- Replace sensor: Install a new compressor discharge temperature sensor if needed, securing it tightly to the discharge line.
- Persistent E7: If E7 returns after cleaning and sensor replacement, the system may be overcharged, undercharged, or have restricted airflow/refrigerant flow. This requires a licensed HVAC technician to diagnose pressures and possibly replace the main control board if its sensor circuit is faulty.