F1
Arctic King Indoor Ambient Temperature Sensor Error (Alternate Code)

Portable or window unit shows F1; unit may run fan but not cool effectively.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective room thermistor, Loose sensor connector, Damaged sensor wiring, Faulty main PCB input

How to Fix / Troubleshooting

Safety: Disconnect power before opening the front panel.

Steps to fix F1:

  • Locate room sensor: Behind the front grille near the air intake, find the small thermistor probe.
  • Inspect and reseat: Ensure the sensor is not broken or dislodged. Follow its wires to the control board and reseat the connector.
  • Test resistance: With a multimeter, measure resistance at room temperature. Replace the room temperature sensor if readings are open, shorted, or far from expected values.
  • Board check: If a new sensor does not clear F1, the main PCB may be defective and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Room Temperature Sensor (Thermistor)