F5
Arctic King Water Tank Full / Condensate Level Fault

Portable unit shows F5 and stops cooling; may run fan intermittently.

Advertisements

Possible Causes

Full internal condensate tank, Blocked condensate drain, Stuck float switch, Faulty water level sensor

How to Fix / Troubleshooting

Safety: Turn off and unplug the unit before draining water.

Steps to clear F5:

  • Drain the tank: Move the portable unit to a location where water spillage is acceptable. Remove the drain plug or cap at the bottom rear and drain water into a shallow pan.
  • Check float switch: Open the lower rear panel (if accessible) and locate the float or water level switch. Ensure it moves freely and is not stuck by slime or debris.
  • Clean drain path: Use a small brush or pipe cleaner to clear any blockage in the drain port and tubing.
  • Sensor check: If the float is free but F5 remains, test the water level switch for continuity as you move the float. Replace if it does not change state.
  • Reassemble and test: Reinstall the drain plug securely, reassemble panels, and restart the unit. If F5 persists, the main PCB input for the level sensor may be faulty and require board replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Level Float Switch
Check Price on Amazon