H5
Arctic King IPM (Intelligent Power Module) Protection / Inverter Overcurrent

Unit shows H5 and will not start compressor; fan may still operate.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted compressor, Shorted inverter transistors, Power surge damage, Loose or burnt wiring to compressor

How to Fix / Troubleshooting

Safety: Unplug the unit. Inverter and IPM circuits are hazardous; do not probe live circuits without proper training.

Steps to address H5:

  • Inspect wiring: Check compressor wiring harness and connectors for burns or loose contacts.
  • Compressor test (advanced): With power off, measure resistance between compressor terminals and to ground. Any short to ground or extremely low resistance between terminals suggests a failed compressor.
  • Inverter board inspection: Look for cracked or burnt IPM module on the inverter PCB.
  • Professional repair: H5 almost always requires replacement of the inverter PCB and possibly the compressor. This should be done by a licensed HVAC technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Inverter PCB
Check Price on Amazon

We may earn a commission from links on this page.