H5
Arctic King
IPM (Intelligent Power Module) Protection / Inverter Overcurrent
Unit shows H5 and will not start compressor; fan may still operate.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted compressor, Shorted inverter transistors, Power surge damage, Loose or burnt wiring to compressor
How to Fix / Troubleshooting
Safety: Unplug the unit. Inverter and IPM circuits are hazardous; do not probe live circuits without proper training.
Steps to address H5:
- Inspect wiring: Check compressor wiring harness and connectors for burns or loose contacts.
- Compressor test (advanced): With power off, measure resistance between compressor terminals and to ground. Any short to ground or extremely low resistance between terminals suggests a failed compressor.
- Inverter board inspection: Look for cracked or burnt IPM module on the inverter PCB.
- Professional repair: H5 almost always requires replacement of the inverter PCB and possibly the compressor. This should be done by a licensed HVAC technician.
Advertisements
Repair Difficulty
Professional Required
5/5