Arctic King
Short Cycling / Thermostat Control Issue
Unit frequently turns on and off (short cycling) without adequately cooling the room.
Advertisements
Possible Causes
Room sensor located too close to cold air outlet, Dirty filter causing rapid temperature swings, Oversized unit for room, Faulty room temperature sensor
How to Fix / Troubleshooting
Safety: Unplug the unit before moving sensors or opening panels.
Steps to reduce short cycling:
- Check sensor placement: Ensure the room thermistor is not directly in the cold air stream. If it is, reposition it slightly away from the outlet so it senses room air.
- Clean filter and coils: Dirty components can cause uneven cooling and rapid shutoff. Clean as described earlier.
- Fan setting: Use a continuous fan setting (if available) to mix room air and reduce localized cold spots.
- Sensor replacement: If the unit still short cycles, replace the room temperature sensor. A sensor reading too cold will shut the compressor off prematurely.
- Room sizing: If the unit is significantly oversized for the room, consider using a lower fan speed or a smaller capacity unit to avoid short cycling.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Temperature Sensor (Thermistor)