Arctic King Thermal Overload / Overheating Protection

Unit runs for a few minutes then shuts off completely and will not restart until cooled down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser airflow, Failing fan motor, Dirty coils, Overheating compressor or control board

How to Fix / Troubleshooting

Safety: Unplug the unit and allow it to cool before inspection.

Steps to address thermal shutdown:

  • Clean coils and filter: Thoroughly clean both evaporator and condenser coils and the air filter.
  • Check fans: Confirm both indoor and outdoor fans run continuously when the compressor is on. Replace any weak or non-running fan motor.
  • Ventilation: Ensure the rear of the unit is not enclosed or blocked. Portable units must have a properly installed exhaust hose.
  • Control board location: Some boards overheat if covered in dust. Gently clean dust from the control box and ensure vents are not blocked.
  • Persistent issue: If the unit still overheats and shuts down, a technician should check compressor current draw and internal thermal protectors. Replacement of the compressor or main control board may be required.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Fan Motor
Check Price on Amazon