E07
Ariston Outdoor Condenser Coil Temperature Sensor Fault

Outdoor unit does not start; indoor unit shows E07 and only fan may run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted outdoor coil NTC sensor, Sensor not in contact with coil, Damaged sensor harness, Faulty outdoor PCB sensor input

How to Fix / Troubleshooting

Safety first: Turn off power at the main breaker before opening the outdoor unit. Beware of sharp metal edges.

  • Step 1 – Access outdoor coil sensor: Remove the outdoor unit top or side panel to expose the condenser coil. Locate the NTC sensor clipped to the coil tubing.
  • Step 2 – Check sensor mounting: Ensure the sensor is firmly attached to the coil. Re-clip or secure it if loose.
  • Step 3 – Inspect wiring: Follow the sensor cable to the outdoor PCB. Look for cuts, rodent damage, or pulled connectors. Reseat the connector.
  • Step 4 – Replace sensor if needed: If the sensor capsule is cracked or the cable is damaged, replace with an Ariston-compatible outdoor coil NTC sensor.
  • Step 5 – PCB diagnosis: If a new sensor does not clear E07, the outdoor PCB sensor circuit may be defective and should be tested and replaced by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Outdoor Condenser Coil Temperature Sensor (Outdoor NTC)
Check Price on Amazon