E08
Ariston Compressor Overcurrent / Inverter Module Protection

Unit attempts to start but stops with E08; compressor does not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted compressor windings, Faulty inverter power module on outdoor PCB, Loose power connections to compressor, Low supply voltage or phase issues (for multi-phase models)

How to Fix / Troubleshooting

Safety first: This fault involves high-voltage power electronics. Turn off power at the breaker and do not touch compressor terminals unless you are qualified.

  • Step 1 – Visual inspection: With power OFF, remove the outdoor unit cover. Inspect the outdoor PCB for burnt components, darkened areas, or a burnt smell.
  • Step 2 – Check wiring tightness: Verify that all screw terminals to the compressor and power input are tight and free of corrosion.
  • Step 3 – Power quality: Ensure the supply voltage is stable and within the range specified on the Ariston nameplate. For three-phase units, confirm no phase is missing (requires a multimeter and electrical knowledge).
  • Step 4 – Reset: After inspection, leave power off for 10 minutes to allow the inverter to discharge, then restore power and test. If E08 returns immediately, do not keep retrying.
  • Technician tasks: A technician should measure compressor winding resistance, insulation resistance, and test the inverter module. Replacement of the outdoor inverter PCB or compressor may be required.