E13
Ariston Outdoor Fan Motor Fault

Unit shows E13; outdoor fan does not run or runs intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor fan motor, Faulty fan capacitor (on AC motor models), Obstructed fan blades, Faulty outdoor PCB fan driver

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before working on the outdoor unit.

  • Step 1 – Inspect fan blades: Remove the top grille and check for debris or bent blades. Clear any obstruction and straighten minor bends carefully.
  • Step 2 – Spin test: With power OFF, rotate the fan by hand. It should move freely. If stiff, the motor bearings are likely worn.
  • Step 3 – Check capacitor (if fitted): Many non-inverter Ariston units use a start/run capacitor for the outdoor fan. Inspect for bulging or leakage. Replace with the same µF rating if suspect.
  • Step 4 – Wiring check: Ensure the fan motor connector is secure on the outdoor PCB.
  • Step 5 – Replace fan motor: If the motor does not run even with a good capacitor and correct wiring, replace the outdoor fan motor with an Ariston-specified part.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.