Ariston Louver Mechanism Jam / Partial Failure

Indoor unit louvers do not move or are stuck in one position, but no error code is shown.

Advertisements

Possible Causes

Foreign object in louver path, Broken louver linkage, Weak louver motor, Misaligned louver blades

How to Fix / Troubleshooting

Safety first: Turn off power before manually moving louvers.

  • Step 1 – Remove obstruction: Inspect the louvers for objects or heavy dust buildup. Clean and remove any obstruction.
  • Step 2 – Manual movement: Gently move the louvers by hand to free them. Do not force if they are stuck hard.
  • Step 3 – Check linkage: Remove the front cover to inspect the plastic linkage arms. Replace any broken pieces.
  • Step 4 – Test motor: Restore power and press SWING. If the motor hums but does not move, replace the louver motor.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Indoor Louver Stepper Motor
Check Price on Amazon