Ariston Short Cycling / Improper Control

Unit frequently turns on and off (short cycling) without reaching set temperature.

Advertisements

Possible Causes

Incorrect thermostat sensor placement, Oversized unit for room, Dirty filters causing temperature stratification, Faulty room temperature sensor

How to Fix / Troubleshooting

Safety first: Turn off power before accessing sensors.

  • Step 1 – Check set temperature and mode: Ensure the unit is not set too close to ambient temperature and that the correct mode (COOL/HEAT) is selected.
  • Step 2 – Clean filters and coil: Dirty filters and coils can cause uneven temperature sensing. Clean as per maintenance instructions.
  • Step 3 – Sensor placement: Verify the room sensor is in the correct location inside the indoor unit and not touching the coil or exposed to direct cold air from the outlet.
  • Step 4 – Avoid obstructions: Do not block the unit with curtains or furniture, which can cause the sensor to read incorrectly.
  • Step 5 – Sensor replacement: If short cycling persists, the room temperature sensor may be faulty and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Room Temperature Sensor (Indoor NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements