H0
Armstrong Air Defrost Control Fault

Outdoor unit does not enter defrost in heat pump mode (for Armstrong Air heat pump models), H0 code or similar displayed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed defrost sensor on outdoor coil, Faulty defrost control logic on outdoor board, Wiring issue between sensor and board, Ambient conditions outside defrost range

How to Fix / Troubleshooting

Safety first: Turn off power at the outdoor disconnect. Coils and refrigerant lines may be very hot or cold.

Steps:

  • 1. Confirm heat pump mode: Ensure the system is actually a heat pump and is operating in HEAT mode with outdoor temperatures low enough to require defrost.
  • 2. Inspect defrost sensor: Locate the defrost thermistor clipped to the outdoor coil tubing. Ensure it is firmly attached and not hanging loose. Check for damaged wiring.
  • 3. Check board connections: Verify the sensor is plugged into the correct terminals on the outdoor control board.
  • 4. Manual defrost test (if supported): Some Armstrong Air boards have test pins or a button to force defrost. Follow the service label instructions. If the unit will not enter defrost, the board may be faulty.
  • 5. Replace sensor if out of range: With power off, measure sensor resistance and compare to the manufacturer’s chart. Replace if readings are incorrect.
  • 6. If H0 persists: The defrost control portion of the board may be defective and require replacement by a technician.