E05
Baxi Outdoor Discharge (Compressor) Temperature Sensor Fault

Unit stops with E05; often occurs in heating mode on Baxi heat pump air conditioners

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted discharge temperature sensor, Sensor detached from discharge pipe, Damaged sensor harness, Faulty outdoor PCB

How to Fix / Troubleshooting

Safety: Turn off power at the isolator. The discharge line can be very hot; allow time to cool.

Steps:

  • 1. Access discharge sensor: Remove outdoor unit cover. The discharge NTC is usually strapped or clipped to the small-diameter copper pipe leaving the compressor.
  • 2. Check attachment: Ensure the sensor is tightly fixed to the pipe with its original clip or strap and insulated if originally wrapped.
  • 3. Inspect cable and connector: Look for heat damage or brittle insulation. Reseat the connector on the outdoor PCB.
  • 4. Test sensor: Measure resistance at ambient temperature and compare with Baxi specifications. Replace if open/shorted or far out of range.

Warning: Do not run the unit with a bypassed or disconnected discharge sensor; this protects the compressor from overheating.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Discharge Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements