E25
Baxi Outdoor PCB Overheat / Heat Sink Temperature Error

Indoor unit shows E25; unit may not start or may shut down quickly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked airflow around outdoor unit, Failed outdoor fan causing PCB overheating, Poor thermal contact between IPM and heat sink, Faulty temperature sensor on PCB

How to Fix / Troubleshooting

Safety: Isolate power before accessing the outdoor PCB.

Steps:

  • 1. Ensure ventilation: Confirm that the outdoor unit has adequate clearance and is not enclosed.
  • 2. Check outdoor fan: Verify the fan runs whenever the compressor is commanded on.
  • 3. Inspect PCB area: With power off, remove the cover and ensure no insulation or debris is blocking the PCB heat sink.

Technician: May need to reapply thermal compound, replace the PCB temperature sensor, or replace the outdoor PCB if overheating persists.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Main PCB
Check Price on Amazon