E25
Baxi
Outdoor PCB Overheat / Heat Sink Temperature Error
Indoor unit shows E25; unit may not start or may shut down quickly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked airflow around outdoor unit, Failed outdoor fan causing PCB overheating, Poor thermal contact between IPM and heat sink, Faulty temperature sensor on PCB
How to Fix / Troubleshooting
Safety: Isolate power before accessing the outdoor PCB.
Steps:
- 1. Ensure ventilation: Confirm that the outdoor unit has adequate clearance and is not enclosed.
- 2. Check outdoor fan: Verify the fan runs whenever the compressor is commanded on.
- 3. Inspect PCB area: With power off, remove the cover and ensure no insulation or debris is blocking the PCB heat sink.
Technician: May need to reapply thermal compound, replace the PCB temperature sensor, or replace the outdoor PCB if overheating persists.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Outdoor Main PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements