Baxi Loss of Heating Capacity (Heat Pump Mode)

Unit does not heat in HEAT mode; blows cool air even after several minutes

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge, Stuck reversing valve, Outdoor coil heavily iced, Defective outdoor ambient or coil sensor affecting defrost

How to Fix / Troubleshooting

Steps:

  • 1. Allow time: In HEAT mode, Baxi heat pumps may take several minutes before delivering warm air. Wait at least 5–10 minutes.
  • 2. Check outdoor unit: Ensure the outdoor fan and compressor are running. Look for heavy ice build-up on the outdoor coil.
  • 3. Defrost cycle: If the outdoor coil is iced, the unit should enter defrost periodically. If it never defrosts, the defrost sensor or PCB may be faulty.
  • 4. Mode test: Switch briefly to COOL mode and back to HEAT to see if the reversing valve shifts (you may hear a click).

Action: A technician should check refrigerant charge, reversing valve operation, and defrost control.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Reversing Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements