Beko Outdoor Fan Motor Failure

Outdoor fan does not run while compressor is operating

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor fan motor, Faulty fan capacitor (on AC motor models), Loose wiring to fan motor, Defective outdoor PCB fan relay or driver

How to Fix / Troubleshooting

Danger: Outdoor units contain live high-voltage parts. Turn off power before working.

  • 1. Visual check: Confirm that the compressor is running (vibration, sound) while the fan is stopped.
  • 2. Inspect fan area: Look for obstructions preventing the fan from turning.
  • 3. Spin test: With power off, spin the fan blade by hand. If stiff, the motor is likely faulty.
  • 4. Check wiring and capacitor: Open the control box and verify that the fan motor wires and capacitor (if present) are intact and connected.
  • 5. Replace motor or capacitor: If the capacitor is swollen, replace it. If the motor still does not run, replace the outdoor fan motor.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Fan Motor
Check Price on Amazon