Beko
Outdoor Fan Motor Failure
Outdoor fan does not run while compressor is operating
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed outdoor fan motor, Faulty fan capacitor (on AC motor models), Loose wiring to fan motor, Defective outdoor PCB fan relay or driver
How to Fix / Troubleshooting
Danger: Outdoor units contain live high-voltage parts. Turn off power before working.
- 1. Visual check: Confirm that the compressor is running (vibration, sound) while the fan is stopped.
- 2. Inspect fan area: Look for obstructions preventing the fan from turning.
- 3. Spin test: With power off, spin the fan blade by hand. If stiff, the motor is likely faulty.
- 4. Check wiring and capacitor: Open the control box and verify that the fan motor wires and capacitor (if present) are intact and connected.
- 5. Replace motor or capacitor: If the capacitor is swollen, replace it. If the motor still does not run, replace the outdoor fan motor.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Outdoor Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.