E1
Black+Decker Room Temperature Sensor (Thermistor) Fault

Unit stops cooling and displays E1 on the control panel; buttons may still respond but compressor will not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted room temperature thermistor, Loose thermistor harness connection on main PCB, Damaged thermistor wiring near evaporator coil, Failed main control board sensor circuit

How to Fix / Troubleshooting

Safety first: Unplug the air conditioner from the wall outlet before removing any panels. Do not work on the unit while it is connected to power.

  • Power reset: Unplug the unit for 5–10 minutes, then plug it back in and try again. Sometimes E1 can be a temporary sensor reading error.
  • Access the front panel: Remove the front grille and filter. On many Black+Decker portable and window units, the room thermistor is clipped near the evaporator coil or behind the air intake grille.
  • Inspect the thermistor: Look for a small probe with two thin wires going to the main control board. Check for broken insulation, corrosion, or a sensor that has fallen out of its clip and is hanging loose.
  • Check connections: Follow the thermistor wires to the main PCB. Ensure the plug is fully seated and not corroded or burnt. Reseat the connector.
  • Test the sensor (advanced): With the unit unplugged, disconnect the thermistor and measure its resistance with a multimeter. Compare to the service manual chart (typically 5–50 kΩ depending on temperature). If it reads open (OL) or 0 Ω, the sensor is defective.
  • Replace if faulty: If the thermistor is damaged or out of spec, replace it with a compatible Black+Decker room temperature sensor. Route the new sensor along the original path and secure it in the clip near the evaporator intake.
  • If E1 persists: After replacing the sensor, if E1 still appears, the sensor circuit on the main control board may be defective and the PCB may need replacement. This is best handled by a qualified technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Room Temperature Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements