E6
Black+Decker Communication Error Between Display Board and Main Control Board

Display shows E6 and the unit may not respond to some commands or may shut down unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or oxidized communication cable between user interface and main PCB, Damaged ribbon cable, Moisture intrusion on control boards, Failed main PCB or display PCB

How to Fix / Troubleshooting

Safety: Unplug the air conditioner before removing the control panel or accessing internal wiring.

  • Power cycle: Disconnect power for 10–15 minutes to allow the control electronics to fully discharge. Reconnect and test. If E6 returns, continue.
  • Access control panel: Remove the front bezel to expose the display/control board. Carefully detach the panel to access the ribbon or wire harness connecting it to the main PCB.
  • Inspect connectors: Check both ends of the communication cable for loose fit, corrosion, or bent pins. Reseat the connectors firmly.
  • Check cable condition: Look for kinks, cuts, or crushed sections of the ribbon cable. Replace the cable if any damage is visible.
  • Dry moisture: If there are signs of condensation or liquid spills on the control board, gently dry the area with a soft cloth and allow the unit to air dry completely before reassembly.
  • Board replacement: If reseating and replacing the cable does not clear E6, either the display PCB or main PCB is likely defective. Replacing these boards should be done by a qualified technician to avoid miswiring or ESD damage.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

User Interface Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements