F4
Blaupunkt Discharge Temperature High / Sensor Error

Unit displays F4 and stops; often associated with compressor discharge temperature issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser coil, Failed outdoor fan motor, Faulty discharge temperature sensor, Overcharged refrigerant

How to Fix / Troubleshooting

Safety first: Isolate power and allow the outdoor unit to cool before touching any components.

Steps:

  • Clean condenser: As with E8, thoroughly clean the outdoor coil and ensure good airflow.
  • Check outdoor fan: Confirm the fan starts reliably and runs at full speed. Replace the Blaupunkt outdoor fan motor if it is intermittent or seized.
  • Inspect discharge sensor: Verify the sensor is tightly attached to the discharge line and wiring is intact. Test resistance and replace if faulty.
  • Refrigerant check: Persistent F4 after airflow and sensor checks suggests a refrigerant charge issue; have a technician verify and correct the charge.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Discharge Temperature Sensor / Outdoor Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.