F5
Blaupunkt
Outdoor Fan Speed Error / Low Pressure Protection
Unit shows F5; may relate to outdoor fan speed or low pressure protection depending on model.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Outdoor fan motor feedback failure, Fan blades obstructed, Low refrigerant causing low suction pressure, Faulty low-pressure switch (if equipped)
How to Fix / Troubleshooting
Safety first: Turn off power before working near the outdoor fan or pressure switches.
Steps:
- Inspect fan: Check that the fan blades are not hitting the grille or debris. Remove any obstructions and ensure the hub is tight on the motor shaft.
- Check motor connector: Ensure the outdoor fan motor plug is secure on the PCB and not burnt.
- Spin test: Rotate the fan by hand; it should move freely. Stiffness indicates bearing failure and need for motor replacement.
- Pressure switch (if present): Some Blaupunkt units have a low-pressure switch wired to the PCB. Inspect wiring and terminals for damage. Do not bypass safety switches.
- Refrigerant diagnosis: If the fan is good and F5 persists, a technician should check system pressures for low charge or restriction.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Outdoor Fan Motor / Low Pressure Switch
Check Price on Amazon
We may earn a commission from links on this page.