F6
Blaupunkt
Current Sensing / IPM Overload Protection
Unit displays F6 and may limit compressor operation or shut down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Inverter IPM overheating, Poor ventilation around outdoor unit, Faulty current sensor on PCB, Partially shorted compressor winding
How to Fix / Troubleshooting
Safety first: Inverter circuitry is hazardous. Only basic external checks should be done by non-professionals.
Steps:
- Improve ventilation: Ensure the outdoor unit has adequate clearance and is not installed in a confined space trapping hot air.
- Clean condenser and fan: Dirty coils or slow fans can cause IPM overheating. Clean and verify fan operation.
- Check for repeated trips: If F6 appears quickly after reset, the IPM or compressor may be failing. Continued operation can cause catastrophic failure.
- Professional testing: A technician should measure compressor current draw and inspect the IPM module on the Blaupunkt outdoor inverter PCB. Replacement of the PCB or compressor may be required.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Outdoor Inverter PCB / Compressor