H3
Blaupunkt
Compressor Overheat Protection
Unit stops with H3; compressor may be very hot to touch.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser coil, Failed outdoor fan motor, Low refrigerant causing high discharge temperature, Internal compressor mechanical fault
How to Fix / Troubleshooting
Safety first: Allow the unit to cool before touching the compressor or discharge line.
Steps:
- Clean and check airflow: As with E8/F4, clean the outdoor coil and verify unobstructed airflow and proper fan operation.
- Check ambient conditions: In very high outdoor temperatures, ensure the unit is not installed in direct sun without shade or in a confined space.
- Monitor runtime: If H3 occurs after long runtimes, the compressor may be overheating due to marginal charge or internal wear. A technician should check operating pressures and temperatures.
- Do not bypass protection: Never attempt to bypass thermal protection or sensors; this can destroy the compressor.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor / Outdoor Fan Motor