P0
Blaupunkt
DC Bus Voltage Protection
Unit displays P0 and may limit compressor speed or shut down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Supply voltage too low or too high, Faulty PFC circuit on outdoor PCB, Loose power terminals, Failing DC bus capacitors
How to Fix / Troubleshooting
Safety first: High DC bus voltages (up to ~400VDC) are present. Only perform external checks unless qualified.
Steps:
- Check mains voltage: Have a qualified person measure supply voltage at the outdoor unit. Correct any supply issues (loose connections, undersized wiring).
- Inspect terminals: With power off, tighten all power terminal screws and check for heat damage.
- Environmental factors: Avoid sharing the circuit with large inductive loads (welders, large motors) that cause voltage spikes.
- PCB issues: Persistent P0 with correct supply suggests a failing PFC or DC bus on the Blaupunkt outdoor inverter PCB, which should be replaced.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Outdoor Inverter PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements