Blaupunkt No Power / Power Supply Failure

Unit will not power on at all; no lights or display on indoor unit.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped circuit breaker or blown fuse, Faulty indoor power supply board, Loose power wiring at indoor terminal block, Faulty main switch or isolator

How to Fix / Troubleshooting

Safety first: Be cautious when working on live circuits. If unsure, call an electrician.

Steps:

  • Check breaker: Locate the dedicated Blaupunkt AC breaker and reset if tripped. If it trips again immediately, do not force it; there may be a short.
  • Verify wall isolator: Ensure any wall-mounted isolator switch is in the ON position.
  • Inspect indoor terminal block: With power off, remove the indoor front cover and check that L and N wires are secure and not burnt.
  • Check for standby voltage: If you have a multimeter and are qualified, verify mains voltage at the indoor unit. If present but the unit is dead, the indoor power supply / main PCB is likely faulty and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Main Control PCB / Power Supply Board
Check Price on Amazon

We may earn a commission from links on this page.