Bosch Insufficient Cooling Capacity / Performance Degradation

Air conditioner runs but does not cool the room effectively (no error code displayed).

Advertisements

Possible Causes

Dirty indoor filters and evaporator coil, Dirty outdoor condenser coil, Low refrigerant charge, Incorrect Bosch unit sizing for room

How to Fix / Troubleshooting

Safety first: Turn off power before cleaning coils.

Steps:

  • Clean indoor filters: Remove and wash filters with mild detergent. Dry completely before reinstalling.
  • Clean indoor coil: If accessible, use a soft brush and vacuum to remove dust from the evaporator fins. Do not bend fins.
  • Clean outdoor unit: Clear vegetation and debris around the Bosch outdoor unit. Gently wash the condenser coil with low-pressure water.
  • Check settings: Ensure the unit is in Cool mode, fan on Auto, and temperature set at least 3–5°C below room temperature. Close doors and windows.

If cooling is still poor: A Bosch technician should check refrigerant charge and system performance. Undersized units may never reach setpoint in extreme conditions.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Indoor Air Filter Set
Check Price on Amazon